+86-572-6588978

How To Manipulate Carbon Molecular Sieve

Jul 21, 2021

Carbon molecular sieve is to manipulate the screening characteristics to separate oxygen and nitrogen. When molecular sieve adsorbs impurity gas, macropores and mesopores only play the role of channel, and the adsorbed molecules are transported to micropores and sub micropores. Micropores and sub micropores are the volumes that really play the role of adsorption. There are a large number of micropores on the outside of the carbon molecular sieve, which allow the molecules with small energy size to disperse into the pores quickly, and limit the entry of large-diameter molecules at the same time. Because the relative dispersion velocity of gas molecules with different sizes is different, the components of gas inclusions can be effectively separated. Therefore, when making the carbon molecular sieve, according to the size of the molecule, the micropores outside the carbon molecular sieve should be dispersed at 0.28 ~ 0.38nm. Within the scope of micropore size, oxygen can be quickly dispersed into the micropore through the micropore orifice, while nitrogen is difficult to reach the separation of oxygen and nitrogen through the micropore orifice. The size of micropore pore size is the basis for carbon molecular sieve to separate oxygen and nitrogen. If the pore size is too large, oxygen and nitrogen molecular sieve can easily enter the micropore and can not play the role of separation; The pore size is too small, oxygen and nitrogen can not enter the micropores, nor can they break up.